Temperature range change

Please add this feature to cart if you want to change temperature working range of the controller.

Reference: 001296

Manufacturer:

Available quantity: 99 Items

    $10.00 tax excl.

    Product Description

     

    If you want to buy TEC controller with changed temperature range, add this service (item) to your cart and specify new temperature range in customer message during checkout.

     

    Attention! Changing stabilization temperature range may change stabilization accuracy. This is caused by working on different voltage levels inside the deivce.

     

    In the table below you can see temperature stabilization accuracy values for different temperature ranges. You can see that actual accuracy depands on range spread not on the exact temperature when the range starts for example.

     

    Please refer to the following abbreviations:

    Tmin – minimum temperature

    Tmax – maximum temperature

    Tstab min – minimum temperaturę stabilization accuracy (at higher temperature of the range)

    Tstab max – maximum temperaturę stabilization accuracy (at lower temperature of the range)

    Temperature range = Tmax - Tmin

     

    Tmin [⁰C]

    Tmax [⁰C]

    Tstab max [⁰C]

    Tstab min [⁰C]

    -30

    0

    0,05

    0,1

    0

    30

    0,06

    0,1

    30

    60

    0,07

    0,1

    60

    90

    0,08

    0,11

     

    Tmin [⁰C]

    Tmax [⁰C]

    Tstab max [⁰C]

    Tstab min [⁰C]

    -30

    30

    0,05

    0,34

    30

    90

    0,07

    0,2

     

    If you need high temperature stabilization accuracy, temperature range is much more important than what Tmin and Tmax you choose: 

     

    Temperature range spread
    Tmax - Tmin [⁰C]

    Tstab max [⁰C]

    Tstab min [⁰C]

    10

    0,05

    0,06

    20

    0,05

    0,07

    30

    0,05

    0,11

    40

    0,05

    0,12

    50

    0,05

    0,17

    60

    0,05

    0,34